English SSC CGL Tier I papers. Free 60-minute mocks, 100 questions, 200 marks; +2 correct and −0.5 incorrect. Source: SSC response sheets preserved by SSC Portal. The marked archived keys have not been independently revalidated against final SSC keys; worked explanations are pending review. A/B/C/D correspond to source options 1/2/3/4.
These topics contain published free SSC questions. Counts reflect the selected language and paper filters. Archived papers show their source and key status above.
No account needed. This session stays in this browser tab; sign in for timed tests, bookmarks and saved performance.
Question 1 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
A Carnot refrigerator works between 250 K and 300 K. Its COP is
Answer and explanation
Correct answer: B
COP = TL/(TH − TL) = 250/50 = 5.
Question 2 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
One ton of refrigeration is equal to about
Answer and explanation
Correct answer: C
1 TR = 211 kJ/min = 3.517 kW, the rate of heat removal needed to freeze one tonne of water at 0 °C in 24 hours.
Question 3 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
In a simple vapour compression refrigeration cycle, the refrigerant enters the compressor as
Answer and explanation
Correct answer: B
Liquid entering the compressor would damage the valves, so the vapour is kept dry.
Question 4 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
The dew point temperature of air is the temperature at which
Answer and explanation
Correct answer: D
On cooling below the dew point, vapour starts to condense.
Question 5 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
The dry bulb and wet bulb temperatures of air are equal when the relative humidity is
Answer and explanation
Correct answer: B
In saturated air there is no evaporation from the wet bulb, so it reads the same as the dry bulb.
Question 6 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
In a vapour absorption refrigeration system, the compressor of the vapour compression system is replaced by
Answer and explanation
Correct answer: C
The refrigerant is absorbed in a solvent, pumped as a liquid and then driven off by heat in the generator, which uses much less work.
Question 7 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
In a vapour compression cycle, the enthalpies at the evaporator exit, compressor exit and condenser exit are 400, 450 and 250 kJ/kg respectively. The COP is
Question 17 · Mechanical Engineering (SSC JE) · Refrigeration and Air Conditioning
Water enters a cooling tower at 40 °C and leaves at 30 °C. The ambient wet bulb temperature is 24 °C. The tower effectiveness (range/(range + approach)) is